2.3 Symbols used
Danger - high voltage!
Hand:
indicates general information and
recommendations.
Bullet point:
•
indicates the tasks to be
performed.
Arrow:
indicates the response(s) to
®
tasks.
Enumeration sign
3
Defi nition of terms
Control medium
The gas that is controlled by the pilot
solenoid valve.
4
Intended area of use
The GEMÜ 0322 - 0326 pilot solenoid
valves are designed as single control
valves, valves for direct mounting or as
valve manifolds. They control a streaming
gas by opening or closing electrically.
The pilot solenoid valves may only be
used providing the product technical
criteria are complied with (see
chapter 6 "Technical data").
Do not paint the screws and the plastic
parts on the pilot solenoid valve!
Use the pilot solenoid valves only for
the intended purpose!
Otherwise the manufacturer liability and
®
guarantee will be void.
Use the pilot solenoid valves only
G
in accordance with the operating
conditions specifi ed in the contract
documentation and in the installation,
operating and maintenance
instructions.
The pilot solenoid valves may only
G
be used in potentially explosive
zones confi rmed in the declaration of
conformity (ATEX).
5
Condition as supplied
to customer
The pilot solenoid valves are supplied as
separately packed components.
The female threads are sealed with caps.
Scope of delivery 0322
Pilot solenoid valve
O-ring
Sealing plugs
Two fastening / mounting brackets
Scope of delivery 0324
Pilot solenoid valve
Hollow bolt
Two O-rings
Gasket
Scope of delivery 0326
Pilot solenoid valve
Two O-rings
Option: Accessories
18/32
WARNING
0322, 0324, 0326