17 Information

Note on directive 2014/34/EU
(ATEX Directive):
A supplement to Directive 2014/34/
EU is included with the product if it
was ordered according to ATEX.

18 Troubleshooting / Fault clearance

Fault
Possible cause
The pilot solenoid
valve doesn't open
Power supply not OK
or doesn't open fully
Return spring faulty
The pilot solenoid
valve doesn't close
Dirt in the valve body
or doesn't close fully
Manual override activated
Medium pressure too low / too
The pilot solenoid
high
valve does not
control correctly
Connections leaking

19 EU Declaration of Conformity

EU Declaration of Conformity
Hereby we,
GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
Fritz-Müller-Straße 6-8
D-74653 Ingelfingen
declare that the product listed below complies with the following directives:
• Low Voltage Directive 2014/35/EU
• EMC Directive 2014/30/EU
Product:
GEMÜ 0322, GEMÜ 0324, GEMÜ 0326
Joachim Brien
Head of Technical Department
Ingelfingen-Criesbach, September 2016
0322, 0324, 0326
Note on staff training:
Please contact us at the address
on the last page for staff training
information.
Should there be any doubts or
misunderstandings in the preceding text,
the German version of this document is the
authoritative document!
Fault clearance
Check power supply and connection, see product label
Replace the pilot solenoid valve
Clean or replace valve body
Unlock the manual override as described in chapter 11.3.
Check medium pressure (see chapter 6 "Technical data")
Check the connections (see chapter 11.1 "Installation")