Battery mounting - GEMÜ 0322
3
7
A
P
4
1
Battery mounting - GEMÜ 0322
1.
Insert O-ring 7 into base recess.
2.
Press the pilot solenoid valves together
and insert brackets 6 into the respective
retainers from below.
3.
The brackets 6 hold the pilot solenoid
valves together and also serve as
fastening elements.
4.
Fasten the pilot solenoid valve battery
with screws 1.
5.
Connect and seal the pressure inlet
tubing to connection "P" 2 (G 1/4).
Only use screwed plugs form A or B,
short design, to DIN 3852!
6.
If applicable, connect and seal the
exhaust tubing to connection "R" 5 (M5)
or mount a silencer.
7.
Connect and seal the outlet tubing to
connection "A" 4 (G 1/4).
8.
Close the open connection "P with
supplied sealing plug 3 and O-ring 7.
9.
All threads must be sealed gas tight.
0322, 0324, 0326
5
7
A
P
2
6
Installation - GEMÜ 0324
The GEMÜ 0324 pilot solenoid
valve is designed for direct
mounting to pneumatic devices.
3
Installation - GEMÜ 0324
1.
Push hollow bolt 3 with applied O-ring 7
through valve body 4.
2.
Push O-ring 7, sleeve 1 and gasket 2
over hollow bolt 3 from the other side.
The larger diameter of sleeve 1 must
face the pilot solenoid valve.
3.
Mount this pilot solenoid valve assembly
to corresponding device 6 with hollow
bolt 3.
4.
Connect and seal the pressure inlet
tubing to connection "P" 4 (G 1/4).
5.
If applicable, connect and seal the
exhaust tubing to connection "R" 5 (M5)
or mount a silencer.
6.
All threads must be sealed gas tight.
23/32
5
7
4
7
1
2
6