DMX512 Control

The unit is equipped with 3-pin XLR connectors for DMX connection. Connect the DMX output of your DMX
controller to the DMX input of the laser. Connect the DMX output of the first unit in the DMX chain to the
DMX input of the next unit. Always connect one output to the input of the next unit until all units are
connected.
At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
Occupation of the XLR connection
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
DMX Indicator
In DMX operating mode, the word 'signal' appears in the display. If the word is flashing, no DMX signal is
received. Maybe the DMX controller is not switched on or there is an error in the cabling. If the word 'signal'
lights up constantly, the device receives a valid DMX signal.

Interconnecting Several Units (Master/Slave Operation)

Several lasers may be interconnected (max.32). Then all slave units can be synchronized and controlled with
the master unit. Connect the DMX output of the master unit to the DMX input of the first slave unit. Then
connect the DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units
have been connected in a chain.

Connection with the Mains

Connect the device to the mains with the power plug.
The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
The earth has to be connected! If the device will be directly connected with the local power supply network, a
disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical
installation. The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum fault current
of 30 mA.
www.eurolite.de
International
L
N
37