Maintenance Interval Table

Machine part
Complete Machine Check the condition, replace damaged
Accessible screws
and nuts
Sprocket chain
wheel (18)
Saw chain (1)
Saw chain (1)
Guide bar (2)
Guide bar (2)
Oiltank (22)

Trouble shooting

Problem
Device does not
start
Inferior cutting
performance
Saw runs with
difficulty, chain
(1) comes off
Chain (1) be-
comes hot,
smoke develop-
ment during saw-
ing, discoloration
of the rail
16
Action
parts if required
Retighten
Check, replace if required
Check, regrind or replace if required
Clean
(also oil after a longer period out of use)
Check
Clean
(also oil after a longer period out of use)
Check, fill up chain oil if required
Possible cause
Mains voltage defective
House protection fuse activated
Defective On/Off switch (10)
Worn carbon brushes
Defective motor
Incorrectly mounted saw chain Mount saw chain correctly
Saw chain (1) blunt
Chain tension insufficient
Chain tension insufficient
Too little chain oil
Before

Fault correction

Check plug socket, cable, line and
plug, where appropriate, repair by
electrical specialist.
Check house protection fuse, see note
Repair by customer service
Sharpen cutting teeth or place on
new chain
Check chain tension
Check chain tension
Check oil level and, where appropri-
ate, refill with chain oil,
check oil automatic system and,
where appropriate, clean oil outflow
duct (
17) or have repaired by
D
customer service
Check fine-tuning for lubrication
system (oil regulation button).
After
every
Each
use
Use

Quicklinks ausblenden: