Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Stihl RE 362 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für RE 362:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

Specifications

Electrical Specifications
Power supply:
Power output:
Fuse (characteristic "C" or "K"):
Protection class:
Type of protection:
1)
Norway only
Hydraulic specifications
Working pressure:
Max. permissible pressure: 25 MPa (250 bar)
Max. water feed pressure:
Max. water throughput:
Water throughput as per
EN 60335 - 2 - 79:
Max. suction lift:
Max. water feed tempera -
ture in the pressurized water
supply:
Max. water feed tempera -
ture in suction operation:
Max. kickback force:
Oil grade (service):
Oil quantity:
1)
Norway only
RE 362, RE 362 PLUS, RE 462, RE 462 PLUS
RE 362
400 V / 3~ / 50 Hz
6.3 kW
16 A
I
IP X5
RE 362
RE 362 PLUS
3.5 - 18 MPa
3.5 - 18 MPa
(35 - 180 bar)
(35 - 180 bar)
25 MPa (250 bar)
1 MPa (10 bar)
1 MPa (10 bar)
1080 l/h
1080 l/h
1000 l/h
1000 l/h
2.5 m
2.5 m
60 °C
60 °C
50 °C
50 °C
51 N
51 N / 49 N
SAE 80W - 90 API GL - 5 SAE 80W - 90 API GL - 5 SAE 80W - 90 API GL - 5 SAE 80W - 90 API GL - 5
730 ml
730 ml
RE 362 PLUS
RE 462
400 V / 3~ / 50 Hz
400 V / 3~ / 50 Hz
1)
230 V / 3~ / 50 Hz
6.5 kW
7.4 kW
1)
16 A / 25 A
16 A
I
I
IP X5
IP X5
RE 462
3.5 - 22 MPa
(35 - 220 bar)
25 MPa (250 bar)
1 MPa (10 bar)
1130 l/h
1050 l/h
2.5 m
60 °C
50 °C
1)
54 N
730 ml
English
RE 462 PLUS
400 V / 3~ / 50 Hz
7.4 kW
16 A
I
IP X5
RE 462 PLUS
3.5 - 22 MPa
(35 - 220 bar)
25 MPa (250 bar)
1 MPa (10 bar)
1130 l/h
1050 l/h
2.5 m
60 °C
50 °C
54 N
730 ml
57

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Re 462

Inhaltsverzeichnis