Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Delivery; Technical Data - FLORABEST 40 V HTA FKTSA 40-Li A1 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Scope of delivery

Q
1 Cordless chainsaw 40 V HTA FKTSA 40-Li A1
1 Saw chain
1 Guide bar
1 Battery pack FAP 40 A1
1 Rapid battery charger FLG 40 A1
1 Guide bar cover
1 Oil bottle with 180 ml chain oil
1 Operating instructions

Technical data

Q
Cordless chainsaw:HTA FKTSA 40-Li A1
Rated voltage:
40 V
No load speed n
:
5800 min
0
Saw chain type:
Oregon 91P045X,
low-kickback
Guide bar type:
Oregon 12" 120SDEA041
Guide bar length:
305 mm
Cutting length:
283 mm
Chain pitch:
10 mm
Chain gauge:
1.2 mm
Chain speed v
:
11 m/s
0
Drive sprocket:
6 teeth
Oil tank volume:
approx. 180 ml
Battery pack:
FAP 40 A1
Type:
Lithium ion
Rated voltage:
36 V
40 V
Capacity:
2.5 Ah (90 Wh)
Number of cells:
10
Rapid battery
FLG 40 A1
charger:
INPUT:
Rated voltage:
100 – 240 V ~ , 50/60 Hz
Power consumption:
160 W
OUTPUT:
Rated voltage:
36 V
Charging current:
3.0 A
Charging time:
approx. 60 min
Protection class:
II /
8
GB
Noise emission value:
Noise measurement value determined in
accordance with EN 60745. The A-rated noise
level of the power tool is typically as follows:
Sound pressure level L
Uncertainty K
Sound power level L
Uncertainty K
Guaranteed sound power
level L
(according to 2000/14/EC amended by
2005/88/EC)
-1
Vibration emission value:
(front handle)
Hand/arm vibration a
(rear handle)
Hand/arm vibration a
Uncertainty K:
u
max.
NOTE
u
:
pA
:
pA
:
WA
:
WA
:
WA
WARNING!
Wear ear protection!
:
h
:
h
WARNING!
The vibration level varies in accordance with
the use of the power tool and may be higher
than the value specified in these instructions in
some cases. There is a risk of underestimation
of the vibration load if the power tool is
used regularly in this manner. Try to keep the
vibration loads as low as possible. Measures
to reduce the vibration load are, e.g. wearing
gloves and limiting the working time. Wherein
all states of operation must be included (e. g.
times when the power tool is switched off and
times where the power tool is switched on but
running without load).
The vibration level specified in these
instructions has been measured in
accordance with a standardised measuring
procedure specified in EN 60745 and can
be used to make equipment comparisons. The
specified vibration emission value can also be
used to make an initial exposure estimate.
86.8 dB(A)
3 dB
96.5 dB(A)
3 dB
100 dB(A)
3.37 m/s
2
3.32 m/s
2
1.5 m/s
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis