• In the default settings, the comfort range is set from 25°C to 28°C:
• The adjustable value range is, irrespective of the type of sensor, +5°C to
+70°C. Take note during the setting of the respective ascertainable tem-
perature thresholds of the sensor.
• Long press the "SENSOR" and " SELECT" buttons simultaneously.
• The display indicates in display A the previously set comfort range-lower threshold, the
comfort symbol and "LO".
• Now set the desired lower threshold by pressing several times or by pressing and holding
the "SELECT" button.
• Briefly press afterwards the "MIN MAX" button. The status display switches to "HI".
• Now set the desired upper threshold by pressing several times or by pressing and holding
the "SELECT" button.
• Return to the normal display again by briefly pressing the "SENSOR" button.
Alternatively you can wait without actuating any button until the device goes back to the
normal display automatically.