Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Installation

Always observe the laser safety notes on this as listed above in these instructions and the legal
provisions and requirements of your country for assembly.
Assembly and installation of the device must be carried out by a specialist familiar with the
hazards and the relevant regulations. Maintenance, operation and commissioning of this device
must only be carried out by qualified persons.
It must not be possible to inadvertently adjust, turn or otherwise change the device's position
after mounting. Simple setting up of the laser does not meet this requirement.
When choosing a location for your device, make sure to avoid impact, vibration, dust, hot and
cold temperatures and dampness. There also must not be any powerful transformers, motors or
other devices with a strong interference emission in the device's proximity.
Never cover the device. Make sure when mounting with other equipment that there is sufficient
ventilation. Maintain a distance of at least 50 cm from other devices and limiting areas. Never
install the laser effect in direct proximity of heat sources. Do not point any strong spotlights or
light sources towards the device. This may cause overheating (danger of fire!).
The laser effect must only be operated at an ambient temperature of 10-40° C.
Do not drill or screw additional screws into the casing in order to fasten the device. This may
expose dangerous voltage to touch.
The device must be mounted out of normal reach.
Easily flammable materials like decorative fabrics must have a distance of at least 50 cm from the
device. Otherwise, such objects may catch fire! The laser beams also must not be pointed at
easily flammable materials.
When mounting the product, make sure that the power cord is neither jammed nor damaged by
sharp edges.
During installation or service work, the area below the place of installation must be cordoned off.
Never stand below the place of installation either.
The installation surface or mounting fixture needs to be designed in a way that it can take 10 times
its load capacity for at least 1 hour without permanent damaging deformation.
It is also essential that the device is secured by means of a second safety restraint that is
independent of the actual mounting supports when installing it in an elevated position. No part
of the installation must fall down if the main suspension system fails.
Observe all relevant regulations of your country when installing the device.
Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical connections)
must be inspected by an official expert.
A yearly inspection by an expert is required.
At least every 4 years, an acceptance test must be carried out by an expert.
34

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis