Herunterladen Diese Seite drucken

Maintenance And Care; Cleaning The Filter - Kärcher IV 100/55 H B1 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für IV 100/55 H B1:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Maintenance and care

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Dust extracting machines are safeguards
for the prevention or elimination of hazards
defined in the regulations of BGV A1.
In order to carry out maintenance work,
the user must disassemble, clean and
service the unit, in so far as this is pos-
sible without endangering maintenance
personnel and other persons. Suitable
precautions include decontamination
before the unit is disassembled. Pre-
cautions must be taken for local filtered
forced air ventilation at the place where
the unit is disassembled, the cleaning of
the maintenance surface and suitable
protection of the personnel.
The outside of the unit should be
cleaned thoroughly and any harmful
substances removed. Alternatively, a
sealed coating may be applied before
the unit is removed from the danger ar-
ea. All unit parts are to be considered
contaminated when they are removed
from the danger area.
In the framework of maintenance and
repair work all contaminated objects
that cannot be cleaned satisfactorily
must be disposed of. Such objects must
be disposed of in impermeable bags in
accordance with the valid provisions for
the disposal of such waste.
During the transport and maintenance
of the appliance the extraction opening
is to be closed with the cap.
Warning
Safety equipment for preventing hazards
must be serviced and maintained regularly.
This means that the manufacturer's staff or
persons trained by the manufacturer must
check the equipment for proper functioning
at least once a year, i.e. check for leaks, fil-
ter damage, functioning of the controlling
elements, etc.
20
Danger
The effectiveness of the filtration of the ap-
pliance can be tested as specified in test
procedure EN 60 335–2–69 AA.22.201.2.
This test must be conducted at least once a
year or even more frequently if this is re-
quired by national regulations. If the test re-
sult is negative, the test must be repeated
using a new H filter cartridge.
No outside help is required for carrying
out basic maintenance and cleaning.
The appliance surface and the inside of
the container should be cleaned regu-
larly using a damp cloth.
Danger
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or high-
er breath-safe masks while carrying out
maintenance tasks (such as changing fil-
ters).

Cleaning the filter

 Switch off the appliance using the On/
Off switch.
 Tilt the fastener for filter dedusting to-
wards the side.
 Move forcefully the handle for filter de-
dusting in an upward and downward di-
rection.
 Place the fastener for filter dedusting in
a vertical position.
If this cleaning does not lead to improve-
ment, the filter can be removed and
washed or replaced (see Chapter "Ex-
changing/replacing the filter").
– 7
EN

Werbung

loading