Herunterladen Inhalt Inhalt Diese Seite drucken

Capacity Measurement - Benning MM P3 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für MM P3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.5 Continuity test with buzzer
-
Select the desired function (Ω,
BENNING MM P3.
-
Switch over to the continuity test ( ) by means of the „SELECT" key 5 of the
BENNING MM P3 (press the key once).
-
Bring the safety measuring lines into contact with the measuring points.
-
If the resistance between the measuring points falls below 50 Ω, the integrated
buzzer of the BENNING MM P3 sounds.
See figure 6:

8.6 Capacity measurement

Before performing capacity measurements, discharge capacitors com-
pletely!
Never apply voltage to the capacity measurement jacks!
This might damage or destroy the device! A damaged device might
represent an electrical hazard!
-
Select the desired function (
BENNING MM P3.
-
Determine the polarity of the capacitor and completely discharge the capacitor.
-
If necessary, make the null balance by means of the „RANGE/ REL Δ (
-
Bring the safety measuring lines into contact with the discharged capacitor
according to ist polarity and read the measured value on the digital display  of
the BENNING MM P3.
See figure 7:
8.7 Frequency measurement
-
In order to measure square wave signals of up to 5 V
function (Hz, %) by means of the rotary switch 7.
-
In order to measure sinusoidal signals of up to 600 V
(V
, Hz, %) by means of the rotary switch 7 and switch over to frequency
AC
measurement (Hz) by means of the „SELECT" key.
-
Please observe the minimum sensitivity for frequency measurements of the
BENNING MM P3!
-
Bring
the
points and read the measured value on the digital display  of the
BENNING MM P3.
See figure 8:
8.8 Pulse-Duty Factor Measurement
-
Select the desired function (Hz, %) at the BENNING MM P3 by means of the
rotary switch 7.
-
Switch over to the pulse-duty factor measurement (%) by means of the „SELECT"
key 5 of the BENNING MM P3 (press the key once).
-
Bring the safety measuring lines into contact with the measuring points and read
the measured value on the digital display  of the BENNING MM P3.
See figure 8:
12/ 2007
Continuity test with buzzer
Capacity measurement
safety
measuring
Frequency/ pulse duty factor measurement
Frequency/ pulse duty factor measurement
BENNING MM P3
,
) by means of the rotary switch 7 of the
) by means of the rotary switch 7 of the
lines
into
contact
, select the desired
SS
, select the desired function
eff
with
the
)" key 6.
measuring
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis