• When working outdoors, only use extension cables
especially approved and appropriately labelled for
outdoor use.
• Do not set up any provisional electrical connections.
• Never bypass protective devices or deactivate
them.
• Only hook up the machine by means of a fault-
current circuit breaker (30 mA).
• The electrical connection or repairs to electrical
parts of the machine must be carried out by a cer-
tified electrician or one of our customer service
points. Local regulations – especially regarding
protective measures – must be observed.
• Damaged mains leads must be replaced by the
manufacturer or one of their service workshops or
a similar qualified person to prevent dangers.
• Repairs to other parts of the machine must be car-
ried out by the manufacturer or one of his customer
service points.
• Use only original spare. Accidents can arise for
the user through the use of other spare parts. The
manufacturer is not liable for any damage or injury
resulting from such action.

Assembly

Your garden shredder is not fully assembled due to
technical packing difficulties.
Assembly tools
Included in the items delivered are:
1 Hexagon socket head wrench 4 mm
Design features, Fig. A
Filling chute, flap, funnel Fig. A
1. Filling chute
2. Safety screw
3. Flap
4. Funnel
• Fit filling chute (1) with the housing open
Front side, bottom
2 flat, round screws M6x16
2 serrated washers Ø 6
2 2 safety cap nuts M6
Rear side, bottom
2 flat, round screws M6x16
2 serrated washers Ø 6
2 safety cap nuts M6
• Close the housing and screw safety screws (2) all
the way in.
• Insert flap (3) into the filling chute, fit the funnel (4)
and fasten in place.
Rear side, funnel
2 flat, round screws M6x20
2 serrated washers Ø 6
2 safety cap nuts M6
Front side, funnel
2 flat, round screws M6x16
2 serrated washers Ø 6
2 safety cap nuts M6
20 English
Insulating mat, chute trim Fig. B
1. 1insulating mat
2. chute trim
3. cover
Insert the insulating mat (1) into the funnel chute from
below.
In doing so, the noise absorbing side (textured) must
lie on the noise opening of the filling chute.
As an alternative, some devices are equipped with
smooth insulating mats with no texture.
Likewise, insert the chute trim (2) into the funnel chute
from below and screw on.
2 self-tapping screws Ø 4,2 x 16
2 washers Ø 5
Screw on the cover (3)
1 lenticular flange head screw M6 x 20
1 serrated washer Ø 6
Your garden shredder is now fully assembled
m Electrical connection
The installed electric brake motor is ready to be put
into operation.
The connection meets the relevant VDE and DIN re-
quirements.
The electric brake motor causes the disc blade to
come to a near immediate standstill after the machine
has been turned off.
Firring, repair and maintenance work on the electric
unit can only be carried out by a qualified electrician.
Important notes
Damaged electrical connection cables
Insulation damage often occurs with electrical con-
nection cables.
Some causes are:
• Pressure points, especially when electrical connec-
tion cables are run through window or door cracks.
• Kinks caused by improper handling or mowing of
the electrical connection cables.
• Cuts resulting from being run over
• Insulation damages caused by pulling the cable out
of wall sockets.
• Cracks resulting from aging of the insulation.
Such insulation damaged electrical connection ca-
bles cannot be used and are, as a result of their insu-
lation damage. LIFETHREATENING!!
Check the electrical cable connections on a regular
basis. When checking the cables, make sure that the
cables are not stuck to the electrical network.
Electrical cable connections built with seal contacts
must meet the relevant VDE and DIN requirements.
Only use electrical cable connections with a rating of
at least H 07 RN or a rubber sheathed cable.
The type rating of the connection cable must be print-
ed on the cable.