ADVICE IN THE EVENT OF PROBLEMS
PROBLEM
display-control panel off
remote control (optional) not working excessive distance from stove
outlet air not hot
no flame appears (remember that it
only appears 5 minutes after pressing
the 0/1 key)
ignition failure
the ignition/off does not start at
the time required
ERR 1- ERR 2 appears on the display
POSSIBLE CAUSES OF SHUTDOWN
If the stove shuts down, the reason is shown on the display.
H1 no depression: problem connected with air circulation;
H2 smoke expulsion motor failure;
SF (H3) flame stop;
AF (H4) ignition failed;
H5 power failure stoppage;
H6 thermocouple failure or disconnection;
H7 excessive smoke temperature.
The message is displayed until the 0/1 key on the panel is pressed.
Do not restart the stove until the problem has been looked into and the cause removed.
To start the stove up again after a shutdown, let the shutdown procedure end (10 minutes marked by a beep) then press
the 0/1 key.
Never unplug the stove while it is shutting down owing to problems. It is important to report what the panel says to the
Dealer.
Advice for each of the cases mentioned above is shown on the next page.
The chimney pots and smoke ducts connected to solid fuel devices must be brushed once a year (check whether there
are regulations on the subject in the country of installation). If inspection and regular cleaning are not carried out, the
probability of a chimney pot fire increases. In the event of a chimney pot fire, proceed as follows:
do not use water to extinguish;
empty the pellet hopper;
contact specialist staff after the accident before starting up again.
27/04/2010
16.35
CAUSE
no mains voltage
too much soot in heat exchanger
the screw feeder has not been filled
build up of unburnt material in
combustion chamber
incorrect setting:
clock
programme enabling
programme enabling for the day
backup battery is drained, inside the
control board
23
Pagina 24
SOLUTIONS
make sure the power cord is
connected check the fuse
(on the power socket)
move nearer to stove
clean heat exchanger from inside the
firebox
fill screw feeder (see ignition
paragraph)
clean combustion chamber
check according to the instructions
on page 22
replace the backup battery