12. Troubleshooting

Consumer switches on/off too frequently
• Set a higher value in the menu "USER SETTINGS", function G10
"SWING SETTING" (default setting is 0.5 °C).
Manual temperature preselection not possible
• First perform programming, see chapter 9. b).
Room temperature is too high or too low
• Set an offset value to adjust the control to the local situation
in the menu "USER SETTINGS", function G9 "TEMP CALIBRATE"
(default setting is 0.5 °C).
Alternatively, you can directly change the temperatures of the
present programming with the function G3 "PROGRAM SET-
BACK".
Adjustable temperature area too small
• Set the desired upper and lower temperature limit correctly in
the menu "USER SETTINGS", function G8 "TEMP LIMITS".
A lower temperature limit of +5.0 °C and an upper limit of
+45.0 °C is pre-set ex works.
The temperature range can be limited accordingly if required.