b) Function G2 "PROGRAM SETTING"

The desired times and temperatures within which the room ther-
mostat activates or deactivates the connected consumer accord-
ing to temperature are set here.
For example, you can specify that a temperature of 20.0 °C ap-
plies from 06:00:00 Am onwards, followed by a temperature of
18.0 °C from 09:00:00 onwards for the rest of the day.
Depending on whether you have selected the heating or cool-
ing mode in "INSTALL SETTINGS" in the menu, the consumer
connected to the room thermostat is activated or deactivated
accordingly.
The connected consumer (e.g. an electrical heater) is activated
in the heating mode if the temperature measured by the tem-
perature sensor drops below the temperature value you have
programmed.
To avoid too-frequent activation/deactivation processes, the tem-
perature must deviate by the temperature hysteresis set in the
function G10 "SWING SETTING" before the consumer connected
to the room thermostat is activated (or deactivated).
Example:
Programmed temperature value:
Temperature hysteresis:
Activation/deactivation process:
Up to 7 different times at which the temperature may change
can be programmed per day (displayed as P1....P7) (step width 10
minutes).
For example, you can specify that a temperature of 20.0 °C ap-
plies from 06:00:00 onwards in the fi rst memory stop "P1" and
a temperature of 18.0 °C from 09:00:00 onwards in the second
memory slot "P2".
Proceed as follows for programming:
1.
After selecting this function G2 "PROGRAM SETTING" and
confi rming with "OK" (5), the number(s) for the weekdays or
day blocks fl ash at the upper display edge.
60
The home technology brand for the entire house. More information at www.sygonix.com
20.0 °C
0.5 °C
At 19.5 °C or 20.5 °C