Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Adhesive Mounting - pyrexx PX-1C Betriebsanleitung

Funk-rauchwarnmelder
Vorschau ausblenden Andere Handbücher für PX-1C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.4 Rooms with a platform or gallery
1/2
1/2
0,5
>16 m² / >2 m
0,5
0,5
Abb. 8
Rooms with a platform or gallery
Allowed
Not allowed
Note the following for rooms with plat-
forms or galleries (area greater than 16 m
at least 2 m long and wide):
f Mount additional device under the
platform / gallery.
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
56

5 Installation

The device is held by a magnetic carrier at
the installation location.
The magnetic carrier can be mounted by
gluing or drilling.
CAUTION
Possible property damage!
Using other fastening material (not
enclosed) or wrong conditions at the
installation location can cause the
device to fall down.
f Use only the supplied mounting
material (adhesive pad or
screws /dowels).
f Ensure that the mounting location is
strong enough, solid, dry, free from
grease, dust and loose paint etc.
f Note that the magnetic carrier
magnetically attracts only from
,
2
one side.

5.1 Adhesive mounting

The magnetic carrier can be mounted us-
ing adhesive assembly as follows:
Easy to maintain and removable ac-
cording to EN 14604:2005/AC:2008
or maintenance-unfriendly but
theft-proof according to
EN 14604:2005/AC:2008
and vfdb 14/01 (Q)
Adhesive mounting according to
EN 14604:2005/AC:2008
When performing this type of installation,
proceed as follows:
(1) Remove magnetic carrier from the device
f To do this, tilt the magnetic carrier
(2) Remove the protective film from the
adhesive pad on the magnetic carrier
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
EN
EN
(3) Press firmly magnetic carrier for about
10 seconds at the mounting position
(4) Taking the device into operation and
setting up
f Observe chapter 6 „Putting into
operation and setup" on page 60
(5) Put the device on the magnetic carrier
5 The device is mounted on the
magnetic carrier
The ultimate strength of the adhe-
sive bond is achieved after about
72 hours.
Adhesive mounting according
to EN 14604:2005/AC:2008
and vfdb 14/01 (Q)
To establish a permanent connection be-
tween the device and magnetic carrier
(e.g., as theft protection), you can addition-
ally mount the device with the supplied
adhesive film on the magnetic carrier.
57

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading