General instructions

The Square is tested in accordance with the international EN 13229 standardization, and has an extra additional
standardization for optimally environment-friendly heating devices related to flue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a flue tube to which several stoves are connected. The flue pipe
has a diameter of 150 millimetres.
The heating device must be placed by an acknowledged installer and according to the installation
!
instructions given below. The national and local rules and regulations for placing and using wood-
burning stoves are equally applicable. WANDERS does not give any guarantee if the Square is
connected or installed incompletely or incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2 dwellings.
Spaces where highly flammable or explosive materials are used.
Spaces where an exhaust system is used or where a mechanical exhaust system is placed, except when the
air supply is taken directly from outside to assure a hazardless combustion.

Preparation

The chimney flue

Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company. Any cut-off valves or stop valves must be removed.
The flue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney flue must always end up in outlet area 1 (see the drawing and the table below)
At the time of placing the stove, the chimney flue must be clean, leak-proof and without obstructions, and
must have a diameter of 150 mm.
Any bends in the flue tube must not exceed 45 degrees.
Ensure that the chimney tube can discharge the flue gases adequately, properly and safely.

Fire Safety

For reasons of fire safety is it important to observe the instructions below before installing the stove.
1. If the floor around the stove is made of combustible material, you must use a floor slab. The floor slab must
measure at least: - 50 cm from the stove on the front side of the door - 30 cm from the stove on the sides
24
1
3
3
A X
X > 23˚
1
X
500 mm
3
X < 23˚