• Never turn the equipment on immediately after transferring
it from a cold environment to a warm environment. Conden-
sation can cause irreparable damage to your equipment.
Allow your device to acclimatize to the temperature of the
room before you switch it on.
3. Description of the Operating Elements
See fold-out for figure
1
1.
3
/
digit LCD display, max. display value: 1999.
2
2.
On/Off switch „0 - 1".
3.
Measurement range switch.
4.
Slide switch „R - L/C" for switching between resistance mea-
surement „R", inductance measurement „L" and capaci-
tance measurement „C".
5.
Input sockets „+" and „−" for connecting measuring leads.
Important!
Please note the max. input parameters.
6.
Battery compartment with cover (attached by screws).
6
4. Use of the Multimeter

4.1 Fitting/Replacing the Battery

Your measuring device will only function correctly when fitted
with a 9-V block battery. If the LED „LOBAT" lights up (battery vol-
tage is less than 7.7 V), you must change the battery as follows:
Disconnect your measuring device from the measuring circuit,
remove the measuring leads from the measuring device, switch
off and use a suitable screwdriver to remove the screw attaching
the battery compartment cover. Carefully remove the cover.
Disconnect the used battery from the connecting terminal and
replace it with a new one of the same type (alkaline). After chan-
ging the battery, relocate the connected battery in the battery
compartment and carefully reclose the housing as described pre-
viously but in reverse order. When closing the battery compart-
ment, check that the cables from the connecting terminals are
not jammed.
Important!
Never operate the measuring device when open. Potentially let-
hal hazard!
Remove used batteries from the measuring device, since even bat-
teries protected against leakage can corrode and release chemicals
liable to damage health or damage the battery compartment.
4.2 Connecting the Measuring Leads
Never use other measuring leads than the ones supplied. Before
connection, check the condition of the connectors or crocodile
clips and that the insulation is not damaged.