The factory setting can be changed as follows:
1. Press the touch key 'MENU' (10) and press the scroll touch keys (7
and 9) until the menu option " SET TEMPERATURE" appears.
2. Confirm the menu option with the touch key 'OK' (5).
The display shows the current setting.
3. Select another temperature with the scroll touch keys (7 and 9).
When the desired temperature is displayed, confirm it with the touch
key 'OK' (5).
4. Press the touch key 'RETURN' (11) to exit the menu.
Water hardness
A "DESCALE!" message is displayed after the appliance has been
operated for a factory set period of time, calculated on the basis of the
maximum quantity of lime scale which may be contained in the water
used. If necessary, this period of operation can be extended, making
descaling less frequent, by programming the appliance based on the
actual lime content in the water used. Proceed as follows:
1. Remove the "Total Hardness Test" strip (in front of your manual) and
dip it fully in the water for a few seconds.
2. Remove it and wait 30 seconds until its colour changes and a
number of red dots are formed. For example, if there are 3 red dots
on the test strip, you must set the water hardness level to 3.
▷ ▷ lmmm = water hardness 1
▷ ▷ llmm = water hardness 2
▷ ▷ lllm = water hardness 3
▷ ▷ llll = water hardness 4
If you no longer have a water hardness test, you can find the data in the
table below.
3. Press the touch key 'MENU' (10) and press the scroll touch keys
(7 and 9) until the menu option "WATER HARDNESS" appears.
Confirm the menu option with the touch key 'OK' (5).
4. The display shows the current setting.