3.2.3. AFNOR NFS 87500 / IRIG-B 122 RECEIVER VERSION
►
Open the clock by unscrewing the bottom of the clock.
►
Change the switch position on the synchronization card onto the "ON" position.
►
Connect the AFNOR NFS 87500 / IRIG-B 122 code (No polarity).
►
Depending on the power supply option, connect the clock to the mains.
☛
The hands are positioned at 12 o'clock and then, after receiving the
code, are positioned according to the received time information.
3.2.4. DCF RECEIVER VERSION
►
Depending on the power supply option, connect the clock to the mains.
☛
The hands are positioned at 12 o'clock and then, 3 to 4 minutes
after receiving the code, are positioned according to the received time
3.2.5. DHW (869 Mhz) RECEIVER VERSION
►
Open the clock by unscrewing the bottom of the clock.
►
Change the switch position on the synchronization card onto the "ON" position.
☛
The hands are positioned at 12 o'clock and then, after receiving the
code, are positioned according to the received time information.
3.2.6. NTP RECEIVER VERSION
A. 230VAC version
►
Connect the clock to the computer network.
►
Connect the clock to the mains.
►
Change the switch position on the back onto the "ON" position".
B. POE version
►
Connect the clock to the POE injector.
►
Change the switch position on the back onto the "ON" position".
☛
The hands are positioned at 12 o'clock and then, 3 to 4 minutes
after receiving the code, are positioned according to the received time
MDE-HANDI-2078V2.2
information.
information. For the advanced configuration,
see section 5. WEB INTERFACE.