Herunterladen Inhalt Inhalt Diese Seite drucken

Protecting Against Rays And Burns; Installing The Welding Shield; Start-Up - Parkside PISG 80 A2 Originalbetriebsanleitung

Inverter-schweissgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- Open windows or vent to ensure
air supply.
- Wear safety goggles and a
mask.
Wear gauntlet gloves made
from suitable material (leather)
on both hands. These must be in
good condition.
Wear suitable aprons to protect
the clothing from sparks and
burns. When required based on
the working method, e.g. welding
overhead, wear a protective suit
and, if necessary, a head guard.
Protecting against
rays and burns
Mark the work area with a
sign „Danger! Do not look into
flames!" to indicate the risk to
the eyes. If possible, shield the
work areas to protect persons
nearby. Keep unauthorised per-
sons away from the welding area.
Walls in the direct vicinity of fixed
work areas should be neither
light coloured nor glossy.
Protect windows against rays
passing through or reflecting at
a minimum to head height, e.g.
with suitable paint.
281479_Inverter Schweissgeraet PISG 80 A1_content_GB_IE_NI.indd 13
286508_Inverter Schweissgeraet_PISG 80 A2_Content_LB3.indb 43
Safety instructions / Installing the welding shield / Start-up
Safety instructions / Installing the welding shield / Start-up
Note: The welding tool is suitable for welding with
electrodes.

Installing the welding shield

Install the handle
on the welding shield
8
as shown in Fig. C.
Install the protective glass
11
shield
as shown in Fig. C.
7
Then fold the three sides of the welding shield.
The two sides each connect to the top with two
press studs.

Start-up

Use electrode retaining clips without protruding
retaining screws meeting today's safety stand-
ards.
Be sure the ON / OFF switch
tion "O" ("OFF") or the main supply cable is
not plugged into the mains socket.
Connect the welding cables according to po-
larity and electrode manufacturer instructions.
Put on suitable protective clothing according to
provisions and prepare the work area.
Connect the earth terminal
Secure the electrode in the electrode holder
Switch on the device by setting the ON / OFF
switch
to the "I" ("ON") position.
9
Set the welding current with the control knob
according to the electrode used.
Note: Please see the table below for the weld-
ing current according to electrode diameter.
Attention:
Do not bring the earth terminal
and the electrode holder
5
direct contact with one another.
Attention: When welding with electrodes
(MMA - manual metal arc welding)
the electrode holder
and the earth terminal
5
lug must be connected to positive (+) or negative
(-) according to the welding rod specifications.
Ø Electrode
welding current
1.6
40 – 55 A
2.0
55 – 65 A
2.5
65 – 80 A
7
on the welding
is set to posi-
9
to the workpiece.
4
.
5
3
4
/electrodes into
4
GB
43
GB/IE/NI
13
28.12.16 12:22
14.02.18 08:50

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ian 286508

Inhaltsverzeichnis