  • DEUTSCH, seite 1
13 Impeller
14 Suction support
15 Steering roller of the chassis with park-
ing brake
16 Floor nozzle holder
17 Chassis
18 Handle of the dirt container
19 Holder for suction pipe
20 Handle of the suction head
21 Rotating knob
22 Suction head
23 Torque motor
24 Exhaust muffler
25 Push handle
26 Nameplate

Start up

 Bring the appliance to working position
- secure it, if required, with parking
brakes.
 Insert the suction hose (not included)
into the suction hose connection.
 Check the fill level in the dirt container
prior to starting work and empty the
container if necessary.
 Ensure that the dirt container has been
inserted properly.
 Attach the desired accessoried (not in-
cluded).

Power connection

Caution
Check direction of rotation of the engine at
every socket change.
Note: With correct direction of rotation a
strong airflow can be felt out of the opening
of the exhaust muffler. Air is suctioned with
incorrect rotation direction.
Illustration
 Check the direction of rotation of the
motor. Exchange the poles on the appli-
ance plug if the rotation direction is
wrong.
Caution
Risk of damage! Do not cover the supply
and exhaust air openings on the suction
head.
Caution
The two flat fold filters must never be re-
moved during vacuuming.
Dirt receptacle
Note: The dirt container needs to be emp-
tied if it is full until about 3 cm below the up-
per rim.
Check the fill level of the dirt container
at regular intervals, as the appliance
does not shut off automatically.

Dry vacuum cleaning

Caution
Please note the following when switch-
ing from wet to dry vacuum cleaning:
If you vacuum dry dust while the filter ele-
ment is still wet the filter will become ob-
structed and may be damaged beyond
repair.
 Dry the wet filter properly before use or
replace it with a dry one.
 Change the filter, if required, according
to instructions under the section "Main-
tenance and Care".
Wet vacuum cleaning
Caution: Constantly monitor the fill level
in the dirt receptacle when vacuuming
high volumes of liquid, as the receptacle
can be filled within a matter of seconds
and could overflow.
Caution
Please observe the local provisions regard-
ing the wastewater treatment.
After the wet vacuuming: Clean the flat-
fold filter. Clean the container with a
damp rag and dry it.
– 2