Herunterladen Inhalt Inhalt Diese Seite drucken

Display Setting - Renkforce MINIPAR 18 x 1 W Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

To return to the main level in the menu, push the button MENU (3).
The installed controller needs approx. two seconds to accept and implement the set-
tings.
If no button has been pushed for 10 seconds, the display (1) will switch off automati-
cally. To reactivate it, push any button.
Once a DMX signal is recognised at the DMX IN input (8), the device will automatically
switch to DMX or slave mode. If no DMX signal is recognised anymore, the device will
automatically return to the previous operating mode.
Menu overview:
Display
Setting
Addr
A001-A512
CHnd
3CH / 5CH / 7CH
SLAU
NO / YES
SOUn
Sd-1 / Sd-2 / Sd-3 Sound-to-Light mode 1 / 2 / 3 (3 different effects)
SP-1 to SP-8
JUNP
JU01 to JU20
FL-0 to FL-4
FAdE
Fd01 to Fd15
AUtO
COLO
C001 to C255
FL00 to FL15
NAnU
r000-r255
G000-G255
b000-b255
bLnd
NO / YES
dISP
NO / YES
38
Function
DMX starting address
Number of DMX channels
Slave mode no/yes
Sound-to-Light (microphone sensitivity low > high)
Colour change operation
(change speed slow > fast)
Colour change operation
(strobe speed slow > fast)
Fade operation (colour change slow > fast)
Automatic mode with changing effects
Static colours
Static colours (strobe speed slow > fast)
Manual colour setting
Brightness red off > full brightness
Manual colour setting
Brightness green off > full brightness
Manual colour setting
Brightness blue off > full brightness
Blackout Mode no/yes
Display alignment turned 0°/180°