Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the
electrical connections) must be inspected by an official expert.
A yearly inspection by an expert is required.
At least every 4 years, an acceptance test must be carried out by an expert.
• Attach the enclosed mounting bracket to the sides of the housing with the thumbscrews if
you have not done so yet. Place the rubber rings between the housing and bracket for this.
• Install the effect light on the ceiling, the wall or a suitable crossbeam with the bracket. The
assembly must never swing freely.
• Secure the device with assembly equipment that is compatible with the attachment surface
and suitable for carrying the weight of the effect light.
• Additionally secure the installation with a suitable safety restraint cable or a safety net. The
safety retention rope or the net must be designed to support the effect light in the event of
failure of the main support system independently of the main attachment.
• Set the desired inclination angle and tighten the thumb screws well.