Pin assignment of the DMX connection: Pin1 = earth / Pin2 = (-) / Pin3 = (+).
Never connect the earth pin GND to the casing earth of the effect light; this may result
in interference in signal transmission caused by ground loops.

b) Setting up a master slave chain

The effect light can be operated controlled by a DMX controller or in a master-slave chain. In that
case, the integrated controller of the master device controls the connected slave devices. Up to
16 devices can be operated in a master-slave chain.
• Connect the DMX OUT (9) port of the master device to the DMX IN (8) port of the first slave
device.
• Connect the DMX OUT (9) port of the first slave device to the DMX IN (8) port of the subse-
quent slave device.
• Proceed as described above with all remaining slave devices.
• Plug an XLR plug with a terminating resistor into the DMX OUT (9) port of the last slave
device (as described in section "Connection of a DMX Controller").