Dimming actuator:
Make sure to observe the applied load! The dimmer
is only suitable for light bulbs and for low voltage
NV halogen lamps with magnetic transformers!
The devices are not intended to be isolated. The
load is not electrically isolated from the mains.
Fuse every transformer on the primary side
according to the manufacturer's specifications when
working with conventional transformers.
Use only safety transformers that conform with
DIN EN 61558-2-6 (VDE 0570 part 2-6).
3
Function
The actuators control connected consumers based
on the radio commands received. Commands are
sent out by actuating buttons, remote operations or
from a software interface. In addition, it is possible
to control actuators with sensors that are taught.
The sensors send (like a button) a command when
an event occurs. More information is provided in the
instructions for the respective sensor.
34