9�2�7 Setting Of The Switch Points For Window Function Out1 - autosen AL001 Bedienungsanleitung

Abstandssensor
Vorschau ausblenden Andere Handbücher für AL001:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Switches off when the object is detected
[nSPx] = switch point "near"; [FSPx] = switch point "far"; FE = window
If the measured value is between the switch point "near" [nSPx] and the switch
point "far" [FSPx], the output is open (when [OUx] = [Fnc])�
Switching state of the outputs
Output function
[Fno]
[Fnc]
Both window limit values ([nSPx] and [FSPx]) work with a switching hysteresis
→ 9.2.4 Hysteresis function / example for output function [Hno].
9.2.7 Setting of the switch points for window function OUT1
► In [OU1] select the output function [Fno] or [Fnc]�
► Confirm with [MODE/ENTER]�
► Select [nSP1] and set the switch point "near"�
► Confirm with [MODE/ENTER]�
► Select [FSP1] and set the switch point "far"�
► Confirm with [MODE/ENTER]�
44
Object distance (D)
D < [nSPx]
D > [FSPx]
[nSPx] < D < [FSPx]
D < [nSPx]
D > [FSPx]
[nSPx] < D < [FSPx]
Output status
open
closed
closed
open