9.2.4 Hysteresis function
The hysteresis keeps the switching state of the output stable if the measured
value varies about the sensing range� In both cases the set and reset points are
symmetrically arranged about the selected switch point [SPx]� The hysteresis
is the distance between set and reset points; it is calculated on the basis of the
repeatability with a safety factor of 1�5�
Example Hno
1� For the output function [Hno] the output switches when the object approaches
and when the set point (A) is reached�
2� When the object is removed again, the output does not switch back before the
reset point (B) is exceeded�
The reset point (B) is above the set point (A)�
1
2
[SPx] = switch point; A = set point; B = reset point
If the output function [Hnc] has been selected, the set and reset points are
reversed� The output switches off when the object approaches� When the object is
removed again, the output switches�