•Dilute the disinfecting product
following the instructions given by the
manufacturer. Attention: using less
d i s i n f e c t i n g p r o d u c t t h a n
recommended may promote bacteria
proliferation at dangerous levels, as
well as using excess active principle
does not improve efficiency.
•Leave the disinfecting agent to act for the
contact time required. If left less time
than required, disinfection may be
ineffective.
•In order to carry out the various
operations correctly, you must proceed
from up downwards, finishing with the
floor.
•After applying disinfecting agent,
remove residues with a final rinse.
•Pay utmost care to clean the discharge
opening, the bottom of the bowl and all
the recessed zones which can to be in
contact with food. Use a cleaner or an
hard bristle brush, if required.
•Dry thoroughly the surfaces to avoid
bacteria proliferation due to moisture;
•We recommend you alternate every 6
months the type of disinfecting agent to
avoid developing resistant forms of
bacteria. Bacteria spores are the most
resistant biological forms and, therefore,
it is recommended you use chloride-
based products.

TROUBLESHOOTING

•Machine does not cool:
•Check that the power plug is properly
inserted and the appliance has electrical
energy.
•The safety device of the compressor
comes into action: wait 5-10 minutes
before restarting the machine. Rapid
and continued start-up attempts do
nothing but prolong the period of
inactivity of the machine.
•Check that the machine is correctly
positioned with the ventilation grids (6)
English
free of any obstructions.
•The paddle does not turn:
•Check that the paddle (5) is properly
attached to the tube and locked with a
special locking ring (4).
•Make sure it is free from obstacles that
prevent it from rotating.
•Make sure the lid is closed in the correct
position: a safety device stops the
paddle when the lid is opened.
•The ice cream was too hard and the
motor has stalled for more than 6". A
safety system has stopped the motor in
order to prevent any damage. Turn off
the paddle motor by turning the knob (2),
let the mixture become softer (turn off the
freezing plant) and restart.
•The machine is noisy:
•Some noise is part of the normal
operating specifications, but if it
becomes excessive contact the Service
Centre to avoid further and more serious
problems.
•The water discharge pipe leaks:
•Replace the gaskets of the water
discharge tap (9). Two additional
gaskets sets (16) are provided with the
machine.
•The plastic sleeve (17) on the lower part of
the paddle is too easy to separate.
•Replace the gasket with the new one.
Four additional gasket (15) are provided
with the machine.
•The paddle does not scrape properly the
sides of the bowl.
•Check that the scrapers (18), (19) and
(20) are not damaged or worn.
•Check that the resilient pads (20) are not
distorted. If they are distorted replace
them with new parts. One set is included.