| Important safety information
• Regularly instruct the personnel about safety-conscious conduct.
Note:
We have carried out a risk assessment for the fan. However, it can only apply to the fan itself. After
installation of the fan, we recommend carrying out a risk assessment of the total system. In this way, you
have the guarantee that there is no risk potential from the system.
2.2
Personnel
The fan may only be used by qualified, instructed and trained personnel. The persons must know the relevant safety di-
rectives in order to recognise and to avoid risks. The individual items of work and qualifications can be found in Table 1
Qualifications, page 6.
Table 1 Qualifications
W W o o r r k k i i t t e e m m s s
Storage, operation / use,
cleaning, disposal
Electrical connection,
commissioning, electrical
disconnection
Installation, Dismantling
Maintenance
Repair
Note:
The operator is responsible for the fact that the personnel has been instructed and has understood the
contents of the operating instructions. If something is unclear, please contact Systemair or his
representative.
2.3
Personal protective equipment
Wear the following protective equipment
• protective working clothes
• protective working shoes
• protective working gloves
• goggles
• helmet
• hearing protection
2.4
Intended use
The fans are intended for installation in ventilation systems. They can be installed both in channel systems and also
with free suction via an admission nozzle and a suction-side contact protection grid. Free blow-out via a contact protec-
tion grid is also possible.
• The fan is suitable for conveying clean air, density of 1.3 kg/m³ and permissible humidity of max. 95 %.
• The maximum permissible operating data on the name plate apply for an air density of 1.2 kg/m³ (sea level) and a
max. air humidity of 80 %.
2.5
Incorrect use
Incorrect use refers mainly to using the fan in an other way than described. The following points are incorrect and
hazardous:
• Conveying of explosive and combustible media
• Conveying of media containing dust or kitchen exhaust air
E E l l e e c c t t r r i i c c a a l l e e x x p p e e r r t t o o r r
m m a a t t c c h h i i n n g g q q u u a a l l i i f f i i c c a a t t i i o o n n
X
X
only by agreement with Systemair!
F F i i t t t t e e r r o o r r m m a a t t c c h h i i n n g g
q q u u a a l l i i f f i i c c a a t t i i o o n n
X
X
GB
T T r r a a i i n n e e d d p p e e r r s s o o n n n n e e l l ( ( s s e e e e
f f o o l l l l o o w w i i n n g g n n o o t t e e ) )
X
315291 | 001