7. Specifi cations
Item
Conditions
Command/
setting enabled or
disabled for each
communication
line
Terminal
Supply voltage
input
Note the
Power
connection
consumption
conditions.
Operating
temperature and
humidity range
Storage
temperature and
humidity range
Mass
7-2
(E)
Reset function
Preset function
Datum point setting
function
Reference point function
Master calibration
function
Command
Comparator value setting
Comparator group
number setting
Start
Pause
Latch
Current value/Peak value
(All axes)
Current value/Peak value
(each unit)
Comparator result
Data
output
Alarm (Communication/
Measuring unit)
Soft ware version
Measuring unit product
information
Input resolution
Display and output
resolution
Settings
Axis addition
Comparator mode (2, 4, 8,
or 16 values in 1 group)
DC 12 to 24 V (11 to 26.4 V)
System total: Max. current 4 A
When the maximum current is exceeded, the connection can be
enabled by providing a power supply to the MG42 hub units that
come later in the connection.
<Details of power consumption for each unit>
MG41 main unit
: 4 W
MG42 hub unit
: 1 W/unit
Measuring unit supply : 1 W/unit
˚
0 to +50
C (no condensation)
_ 10 to +60
˚
C (20 to 90 % RH)
MG41 : 300 g
MG42 : 250 g
Description
Ethernet
Remarks
When master
calibration function
is not used
Use a power supply
with a current that
is 4 A or higher.
(Recommended: +24 V)
(for every six MG42
hub units)
MG41-NE / MG42