Herunterladen Inhalt Inhalt Diese Seite drucken

Mains Connection; Initial Use - Schaudt LAS 1218-2 Bedienungs- Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instruction Manual and Installation Instructions LAS 1218-2

Mains connection

Before starting up
16
2.3.2
Mains connection
DANGER!
Y
230V mains voltage carrying parts.
Danger of death due to electric shock or fire:
Only carry out electrical work once the 230V supply has been discon-
F
nected.
The mains must be connected as follows:
to a insulated distribution unit with protective contact
F
to a socket with protective contact (isolated ground or suitable plug
F
connector from WAGO
The power cord must be of type H05VV-F 3x1.5.
The mains cable must have a strain relief where required.
2.4

Initial use

2.4.1
Checks prior to initial use
Ensure that the batteries are connected properly (only for initial use, ope-
ration without battery is possible in general).
2.4.2
Setting battery type
Establish battery type.
DANGER!
Y
Incorrect setting of the battery selector switch.
Risk of explosion from build-up of electrolytic gas, defective battery, defec-
tive battery charger or as a result of too high a battery operating tempera-
ture (above 30 °C):
Move the battery selector switch to the correct position.
F
The battery charger is to be used solely for connecting to the 12V
F
power supply with rechargeable 6-cell lead-gel or lead-acid batteries.
Do not use any unsuitable battery types.
Store batteries in a place with adequate ventilation (or provide integrated
ventilation). Follow the instructions provided by the battery manufacturer.
Fig. 8
Battery selector switch lead-gel-/lead-acid battery.
®
, depending on LAS 1218-2 variant).
lead-acid
Date: 06.11.2014
lead-gel
810.523 BA / EN