Instruction Manual and Installation Instructions LAS 1218-2
Fusing
1.1.1.1
Auxiliary charger
Deliverables
10
Select cable cross-sections in line with EN 1648-1/-2. The maximum current
load must not exceed 90% of the individual fuse rating.
Recommended cable cross-sections:
Line length*
(sum of supply and return lines)
Up to 4 m
Up to 8 m (only for living area battery)
Up to 12 m (only for living area battery)
Fuse the supply lines as follows:
2
with 1.5 mm
cable cross-section
F
2
with 2.5 mm
cable cross-section (or greater)
F
Connection as for auxiliary charger to the electroblock
The LAS 1218-2 battery charger can also be used as an auxiliary charger for
a Schaudt electroblock. Suitable for use here are all Schaudt electroblocks
that include the LAS charger module and have the 2-pin MN connector (e.g.
EBL 99) or Minifit connector (e.g. EBL 220) for an auxiliary charger. See the
instruction manual for the electroblock, "Suitable accessories".
The following parts are supplied for this application:
Item number 999.085 with MNL connector
F
Item number 999.161 with Minifit connector
F
2
3
Fig. 2
Connector set deliverables
Pos.
Qty
1
1
2
1*
3
1*
* Pos. 2 and 3 as an alternative depending on electroblock to be connected
Date: 06.11.2014
Cable cross-section
2
2,5 mm
2
4,0 mm
2
6,0 mm
Name
LAS 1218-2 battery charger, earthing type plug
connection example
Connector cable, 1.7m with Minifit connector
Connector cable, 1.7m with MNL connector
10 A
20 A
1
810.523 BA / EN