Instruction Manual and Installation Instructions LAS 1218-2
Environment
Minimum clearance
Fitting
8
2

Installation instructions

2.1

Introduction

These installation instructions are aimed at trained personnel.
They contain important information on the connection and safe operation of
the device. The safety information provided must be observed.
Always follow the relevant instruction manual in addition to the installation in-
structions.
The following applications are described for the electrical connection (with
the appropriate deliverables):
Auxiliary charger on electroblock (section 1.1.1.1)
F
Direct connection to living area and starter battery (section 1.1.1.2)
F
Connection to additional battery (e.g. when using in conjunction with
F
an inverter) (section 1.1.1.3)
2.2

Mechanical installation

2.2.1
LAS 1218-2 battery charger
This device is intended for installation into a vehicle.
Y
The device was designed for floor installation.
Install in a dry, sufficiently ventilated location. No condensation is allowed
to form on the device. To prevent a build-up of heat, ventilation holes fa-
cing the living area must be provided in the upper and lower areas of the
place of installation. Its cross-section is based on the size and average
temperature of the place of installation.
Keep a minimum clearance to the surrounding fixtures and fittings:
Maintain a gap of at least 5cm on all sides (except mounted side).
F
Whilst in operation, the ambient temperature must not exceed +40 °C,
F
measured 2.5 cm away from the sides of the device.
Screw the battery charger onto a firm, flat base with four screws (5mm
diameter).