Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Cause - Storch Hot Box 240 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Hot Box 240:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Caution:
Switch the device completely off if the burner remains ac-
tive despite having closed the water jet gun. Immediately
contact customer service.
Fault
Heating does not reach
the specified tempera-
ture
Fan motor not active
System does not ignite
Insufficient oil
atomisation
No oil pressure
Solenoid valve does not
open

Possible cause

Switch not in position 1
Fuel oil tank empty
Fuel oil filter dirty
Heating coil furred up
Flow monitor faulty
Temperature controller not set high enough Set to desired temperature
Temperature controller faulty
Burner fuse faulty
Trigger electrodes incorrectly adjusted
Ignition cable, ignition electrodes,
electrode plugs or ignition transformer
faulty
Burner nozzle worn
Insufficient oil pressure
Oil pump faulty
Catch clutch faulty
Fuel oil filter dirty
Temperature set to an insufficient value
Insufficient water volume
Heating coil furred up
Switching the unit off
Switch the temperature controller to "O".
Operate the device until the temperature has dropped to
between 40 - 50° C.
Remedy
Switch on
Top up
Clean
Decalcify
Replace
Replace
Replace. Determine cause
Adjust
Check and replace
Replace
Set to approximately 8 bar
Replace
Replace
Clean
Set to desired temperature
Determine cause
Decalcify
47