Commissioning
Fill the fuel oil tank with light fuel oil or diesel fuel.
Caution:
The oil pump may be damaged if the system is operated
without having filled any fuel. Please ensure water does
not reach the fuel oil tank (this will damage the oil pump).
Frost protection
Frost damages devices in which the water has not been
completely drained. The best way to protect the device
from frost is to store it in a frost-free place.
Do not direct the water jet at persons or animals (risk of
injuries from pressure and heat).
Do not direct the water jet at the device or any other electri-
cal components (risk of short circuits and other damage).
Electrical connection
The voltage stated on the type plate must correspond to
the power supply voltage. The power cable must be pro-
tected by a 16A fuse. Fuses with higher values are not per-
mitted. Install an RCD on site. Electrical connections and
fusing must be implemented by specialists only.
Connect the device to sockets that have been correctly in-
stalled as per VDE and energy supplier regulations only.
Exclusively electricians must perform work on electrical
device components.
Additional safety precautions and instructions on hand-
ling electrical energy
1. Connect the device to correctly installed power supplies
only.
2. Check the cables for damage before use.
3. Connections must be dry and must not lie on the ground.
4. Do not touch plugs with wet hands.
5. Any extension leads used must always be fully removed
from the drum and have a sufficient cable diameter (2.5
mm²) to prevent short circuits or the cable from overhea-
ting (scorching).
It is not permitted to use the device in explosive environ-
ments
Use suitable fuel only: fuel oil, light oil or diesel fuel.
Do not use unsuitable fuels, as this may cause risks, for
instance the risk of explosion, deflagrations or risk of fire.
Operators must continuously monitor fuel-powered heating
modules during operation.
Operation
Device switch to "O"
Temperature controller to "O"
Water supply
Connect high-pressure cleaners or water hoses to the con-
necting nipples indicated with "EIN".
Completely open the tap if the system is connected to a
water pipe.
Water input pressure at minimum 4 bar, 9 l / min., at ma-
ximum 180 bar, 18 l / min.
Inlet side connection
Connect the high-pressure hose to the connection nipple
indicated with "AUS".
Insert the device plug into the socket, open the water sup-
ply or switch on the high-pressure cleaner. Activate the
shut-off cock at the heating coil outlet until a sufficient
amount of water escapes. The device is now ready for ope-
ration.
Hot water operation
Set the device switch to the "1" position and switch the
burner on. Set the desired operating temperature on the
temperature controller.
Caution:
The maximum permissible temperature is 80° C if the de-
vice is operated with the Krake 80 high-pressure cleaner.
Switch to the "Brenner EIN" position to activate the burner
and trigger continuous ignition at the trigger electrodes.
The solenoid valve in the fuel oil supply switches on if wa-
ter is removed.
The solenoid valve immediately and automatically swit-
ches off upon closing the water jet. The temperature con-
troller and the flow monitor control the opening and closing
of the solenoid valve.