Operation
The fluid level must be minimum 3 cm (SCP
1200) or 8 cm (SDP 14000) for the pump to
suck in automaticallt.
If the liquid level is less than 4 cm (only
SCP 12000), proceed according to instruc-
tions in the chapter of flat suction.
 Plug in the main plug.
The IQ Level Sensor controls the pumping
operations.
The pump starts when the fluid level reach-
es the IQ Level Sensor. The pump switches
off automatically after 10 to 60 seconds
(depending on the ambient conditions)
when the fluid level falls below the IQ Level
Sensor. The pump automatically conducts
the adaptation to the necessary trail time/
pump time. Thi setting remains saved for a
max. of 24 hours or until the mains plug is
pulled out. If the mains plug is pulled prior
to the 24 hour time period, or after the 24
hours have elapsed, the pump will auto-
matically set the trail time/pump time to the
set value of 10 seconds.
The optimising of the trail time/pump time
prevents frequent switching on and off of
the pump during rapidly increasing water
levels. In this case, the pump will work even
more effectively, the higher the IQ Level
Sensor is installed.
Note:
Dry run leads to increased wear, switch the
pump off within three minutes in case of a
dry run.
Flat suction (only SCP 12000)
In flat suction mode, the fluids can be
sucked off up to 1 mm of residual height.
 Fold in the folding feet
 Set the IQ Level Sensor to the lowest
switching height (very bottom of the
guide rail).
 When the height of the remaining fluid
is less than 20 mm, press the deaera-
tion key or plug in and disconnect the
pump many times till the fluid is sucked
in.
16

Finish operation

 Disconnect the main plug from the
socket.

Maintenance and Care

Danger
Turn off the appliance and remove the
mains plug prior to any care and mainte-
nance work.
Note
Contaminations can accumulate and lead
to malfunctions.
 Rinse the pump with clean water after
use.
Especially after running chlorinated wa-
ter or other liquids that leave residue
behind.
 In order to ensure a reliable switching of
the pump, the IQ Level Sensor should
be cleaned with a cloth (at least every 2
to 3 months).
The appliance is maintenance-free.