Herunterladen Inhalt Inhalt Diese Seite drucken

Finish Operation; Maintenance And Care - Kärcher BPE 4200/50 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BPE 4200/50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Finish operation

Turn off the appliance.
Disconnect the main plug from the sock-
et.
Rinse the pump after every use if you
use to transport water with additives.

Maintenance and Care

Caution
First pull out the plug from the mains before
carrying out any tasks on the machine.
Open the connected shutoff valves to relief
pressure and reclose them. The system is
free of pressure.
Check pre-filter regularly for dirt. If it is vis-
ibly dirty, proceed as follows:
Illustration
Unscrew the lid of the filling nozzle.
Remove the pre-filter and the built in
backflow valve and clean them under
flowing water.
Illustration
Unscrew the lid from the discharge
opening and catch the escaping water.
Remove the safety device and the flow
meter from the discharge opening.
Completely rinse the dirt residues from
the floor of the fill neck.
Install the components in reverse order.
Pay attention to correct positioning!
Screw the lid tightly onto the discharge
opening
Maintenance
The appliance is maintenance-free.
Empty water in the pump using the drain
opening (item 5) for winter or extended
storage.
Swing the device until all the water is
gone.
Store the appliance in a frost free area.
8
18 English
Deutsch
Storage
CE declaration
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
Product:
Pump
Type:
1.645-xxx
Relevant EU Directives
98/37/EC
2006/95/EC
2004/108/EC
2000/14/EC
Applied harmonized standards
EN 55014–1: 2006
EN 55014–2: 1997 + A1: 2001
EN 60335–1
EN 60335–2–41
EN 61000–3–2: 2006
EN 61000–3–3: 1995 + A1: 2001 + A2:
2005
Applied conformity evaluation method
Appendix V
Sound power level dB(A)
BPE 4200/50
Measured:
82
Guaranteed: 84
BPE 5000/55
Measured:
85
Guaranteed: 87
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Head of Approbation
CEO
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bpe 5000/55

Inhaltsverzeichnis