Operation

Description of the Appliance

1 Power cord with plug
2 Level sensor
3 Level sensor stopper
4 Carrying handle
5 Connection nozzle
6 Hose connection

Preparing the Appliance

Illustration
 for a 3
/
"(19mm) or 1"(25,4mm) hose,
1
4
the hose connection must first be sawn
off.
Illustration
 Screw the suction hose with the union
joint to the pump.
Push the hose on the hose connection
and fasten it with appropriate hose clip
Illustration
 In automatic operations mode, set the
required switching height by clamping
the level sensor cable in the stopper.
Illustration
 In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
Illustration
 Attach the pump to a rope and lower it
into the liquid to be pumped.
In order to prevent blockage of the in-
take area, do not place the pump onto
the floor of the pool.
Illustration
 The flow height indicates the height dif-
ference between the water level and
water exit at the end of the flow hose.
You have to adhere to the flow height
for the pump to flow. This must be ob-
served throughout the entire pump run,
as the flow height will increase with a
decreasing water level (due to the
pumping).
14
The minimum liquid level for the pump to
properly suck in liquids is 10 cm.
 Insert the mains plug into the socket.
Automatic operation
In the automatic mode, the level switch au-
tomatically controls the pumping opera-
tions. The pump switches on or off when
the fluid level reaches the height that has
been set.
Manual operation
In manual opertions the pump remains
switched on continuously.
Note:
Dry run leads to increased wear and tear;
do not leave the pump unattended when it
is running. Switch off the pump within 3
minutes of dry running.

Finish operation

 Disconnect the main plug from the
socket.