b) Remove the cartridge strip from the tool carefully.
c) If a cartridge fails to fire or misfires, always proceed
as follows:
1.Keep the tool pressed at right angles against the work-
ing surface for 30 seconds.
2.If the cartridge still fails to fire, lift the tool away from
the working surface, taking care to avoid pointing it
at yourself or other persons.
3.Load the next cartridge on the strip by cycling the tool.
Use up the remaining cartridges on the strip and remove
the used cartridge strip from the tool. The (partly) used
cartridge strip must then be disposed of suitably in
order to prevent further use or misuse of any unfired
cartridges.
d) Do not attempt to forcibly remove cartridges from
the magazine strip or tool.
e) Unused cartridges must be stored in a dry, high
place, locked up or out of reach of children.
5.1.7 Requirements to be met by users
a) The tool is intended for professional use.
b) The tool may be operated, serviced and repaired only
by authorized, trained personnel. This personnel must
be informed of any special hazards that may be encoun-
tered.
c) Always concentrate on your work. Proceed carefully
and do not use the tool if your full attention is not on
the job.
d) Wear non-slip shoes when working outdoors.
e) Avoid unfavorable body positions. Work from a secure
stance and stay in balance at all times.
f) Keep the arms flexed while using the tool (do not
straighten the arms). If you experience pain or feel
unwell, stop using the tool immediately.

6. Before use

6.1 Check the tool
Check that no cartridge strip is loaded in the tool. If a
cartridge strip is present in the tool, push it forward
in the direction of cartridge transport until it can be
gripped at the cartridge exit opening and pulled out
of the tool.
Check all external parts of the tool for damage at reg-
ular intervals and check that all controls operate prop-
erly. Do not operate the tool when parts are damaged
or when the controls do not function correctly. If nec-
essary, have the tool repaired at a Hilti service centre.
Printed: 08.07.2013 | Doc-Nr: PUB / 5069855 / 000 / 01

5.1.8 Personal protective equipment

The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat and ear pro-
tection while the tool is in use or when checking the
tool for faults etc. The user must also wear protective
gloves.
Check the piston stopper and piston for wear and
ensure that the parts have been fitted correctly.