4. Operation

4.1. Setting the Output Voltage of CH1 and CH2
1.
Connect the power supply to the power source.
2.
Press the POWER SWITCH [1] to turn on the power supply.
3.
Press AUTO CURRENT CUT OFF PROTECTION KEY [2] to activate output and the OUTPUT
INDICATOR [3] will on.
4.
To set CH1, use the CH1 VOLTAGE TUNE KNOB [6] to adjust CH1 voltage to give a desired
output voltage.
5.
Connect the circuit to the TERMINALS [21,22]
6.
When the CH1 CV/CC INDICATOR [5] is in red color, adjust the CH1 CURRENT TUNE KNOB [4]
to give a suitable current.
7.
To set CH2 voltage, repeat the above steps use CH2 VOLTAGE TUNE KNOB [11], short MAIN
TERMINAL [18,19] and CH2 CV/CC INDICATOR [12] instead.
Remarks:
If CH2 cannot be adjusted, check the TRACKING MODE SELECTION KEY [14, 15] is not
pressed.
If want to preset a desired current output before connecting to the circuit, read Section 4.2
first.
Caution:
Make sure the INPUT VOLTAGE SELECTOR [26] set to a correct position Otherwise; it will
damage the power supply.
Do not short the MAIN TERMINALS over 1 minute; it will damage the power supply.