4.3. Setting Normal Mode
1.
Release both TRACKING MODE SLECTION KEY [14, 15].
2.
In independent mode, CH1 and CH2 is two independent power supply unit, voltage or current can
be adjusted separately.
3.
Adjust CH1 or CH2 VOLTAGE/CURRENT KNOB [4, 6 / 11, 13] to set the desired value.
4.
Connect the circuit to the CH1 or CH2 terminals.
4.4 Setting Series Tracking Mode
1. Press TRACKING MODE SLECTION KEY [14] and release TRACKING MODE SLECTION KEY
[15] to enable series tracking mode. In series tracking mode, CH2 output voltage and current value
follows CH1 setting. The output voltage is double to the CH1 display value.
2. Turn CH2 CURRENT KNOB [13] clockwise to maximum current output, and then use CH1
CURRENT KNOB [4] adjust the desired current output value. (Reference to Section 4.2)
3. Use CH1 VOLTAGE KNOB [6] to adjust the desired voltage output value.
4. Connect the circuit to the CH1 "+"TERMINAL [22] and CH2"-"TERMINAL [18] to get double
voltage output.
5. For the bi-polar DC power supply with common ground, connect CH2 "-" TERMINAL [18] to "GND"
GROUNDING TERMINAL [20]. CH1 "+"TERMINAL [22] is the positive output and CH2 "-
"TERMINAL [18] is the negative output.
Illustration of independent mode
Illustration of series tracking mode