d) „History" display for energy consumption per day
This display shows the already used energy in kilowatt hours „kWh"
and the thus calculated costs for tariffs 1 and 2. The display can be
differentiated from the current day (today) until 9 days in the past.
Via the two arrow keys (3 and 4) the days can be browsed back and
forwards. This is illustrated under the display masking „Today", e,.g.
as „1" to „9".
Via this function peak days can be directly analysed on the device.
By pressing the „MODE" key for at least 3 sconds, all displays of „Consumption", „History",
„ON time" and „Forecast" are reset to nill, and the „MEM" memory deleted.
To switch the measurement displays, click the „MODE" (5) key for the next or the „Continue" arrow key
(7) for the previous display. Every time you press, you switch the display.
e) „ON time" display for operating time per day
This display shows the operating time (REC time) and the effective
running time (ON time) of the electric consumption. This function
allows establishing the actual running time, such as with a fridge. A
fridge switches the cooling circuit on with a thermostat, which results
in pauses.
The display can be differentiated from the current day (today) until 9
days in the past.
Via the two arrow keys (3 and 4) the days can be browsed back and forwards. This is illustrated under the
display masking „Today", e,.g. as „1" to „9". After the „-9" display, the entire time (total) is displayed.
Via this function peak days can be directly analysed on the device. The time is displayed
in the decimal system. Example: 1,700 h = 1 h 42 m (700 : 16.66 = 42 minutes ).
By pressing the „MODE" key for at least 3 sconds, all displays of „Consumption", „History",
„ON time" and „Forecast" are reset to nill, and the „MEM" memory deleted.
To switch the measurement displays, click the „MODE" (5) key for the next or the „Continue" arrow key
(7) for the previous display. Every time you press, you switch the display.