Electrical connection

The instructions given below are
designed specifically for a
qualified installer and should
aid him or her to perform all
installation, adjustment, and
maintenance operations with
absolute precision and in
compliance with all current
legislation and regulations. We
strongly recommend that all
operations for the installation of
your oven be carryed out by
Qualified
accordance with existing rules
and regulations.
Electrical connection
Prior to making the electrical connection,
make sure that:
— the protection fuse and the domestic
wiring system are suitable to carry the
total electric load of the oven (see rating
plate);
— your domestic wiring system has an
efficient earth connection in compliance
with rules and laws in force;
— the wall socket or the omnipole switch
used for the electrical connection can
easily be reached after the oven is built
in.
This appliance is delivered without an
electric supply cable, therefore, you will
have to fit to it a supply cable with standard
plug, suitable for the total electric load
shown on the rating plate. The plug is to
be inserted into a suitable wall socket. If
you require a direct connection to the
electric network (mains), it will be necessary
to fit between the appliance and the mains
Personnel
in
an omnipole switch, with a minimum gap
between contacts of 3 mm, suitable for
the required load and in compliance with
rules in force. The green & yellow ground
wire must not be interrupted by the switch
and it should be 2-3 cm. longer than the
other cables. The supply cable must in all
cases be laid out in such a way as to ensure
that it does not reach at any given point a
temperature 50°C higher than the ambient
temperature.
Suitable power supply cables are the
following types, considering the respective
necessary section of cable: H07 RN-F,
H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F.
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel
competencies, in accordance with
the current regulations.

Terminal block

The oven has an easily accessible terminal
block, which is meant to work with an
electric single-phase rate of 230 V.
The Manufacturer disclaims any
liability
in
accident-preventing rules are not
observed.
electrolux 33
with
similar
case
these