14. Troubleshooting
The table below contains a list of fault symptoms and explains what you can do to remedy the problem if your equip-
ment fails to work properly. If the problem still persists after working through the list, please contact your nearest
service workshop.
Fault
The motor doesn't
start.
The motor doesn't do
anything, the safety
default switches on.
The motor is
overloaded the safety
default switches on.
The shredder intake is
diminished, reduced
cutting capacity.
Excessive vibrations/
noise
Possible cause
The upper housing unit is not properly
closed.
The extension cable is defective.
No current is coming out of the outlet.
The switch is defective.
The motor is defective, the capacitor
is defective
Shredder material is obstructing the
blade disc.
The extension cable has an insufficient
cross section
The cable between the power system
connection and the shredder is too
long.
The quantity of wet shredded material
is too high.
The blade and output areas are
clogged.
The blade is dull.
The cable between the power system
connection and the shredder is too
long.
The blade is either dull or worn out.
Blade nut/bolt loose
Cutting blade damaged
Machine damaged internally
www.scheppach.com
Remedy
Screw in the safety thoroughly
Exchange the extension cable or repair it.
Check the mains fuse.
Check/change
Check/change
Pull the main plug, open the housing and
clean it out.
Choose an extension cable with a larger
cross section
Create the shortest possible way between
the power system connection and the
shredder.
Select a smaller quantity of shredded
material. Now and then, include dry
shredding material
Pull the main fuse, open the housing and
clean it out.
Resharpen or change
Choose an extension cable with a larger
cross section.
Turn blade, sharpen blade or replace
entirely.
Tighten blade nut/bolt
Replace blade
Contact Service Agent
GB | 31