Sharpening the blade
• In resharpening the blade (19), pay close attention
to maintaining an even blade-diameter so as to
avoid an imbalanced blade.
• In resharpening the blade, a maximum of only 2 mm
may be removed from each cutting edge.
Install Blade
• Upon reinstallation, the blade disc (19) must be
mounted exactly as before.
• In mounting the blade, lubricate the flat head screws
(20) and tighten well.
• Tighten the countersunk screw firmly.
• Mount the aluminium cover.
• Use the locking screw to close the housing
• The device is ready for operation.
Overload protection
In the event of overload, e.g. due to branches that are
too thick, the equipment automatically switches off.
After a short cooling period (approximately 5 minutes),
press the reset switch (7).
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
28 | GB
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• Before commissioning, ensure that the mains volt-
age matches with the operating voltage on the type
plate.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
• The product meets the requirements of
EN 61000-3-11 and is subject to special connection
conditions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connection
points that have a continuous current-carrying ca-
pacity of the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish to
operate the product meets the requirement named
above.
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their
representative to avoid safety hazards.
With a single-phase a.c. motor, we recommend a C
16A or K 16A fuse for machines with a high start-up
current (from 3000 Watt)!