• The adjustable stop rail (27a) must be fixed far
enough in front of the innermost position that the
distance between the stop rail (27a) and the saw
blade (5) amounts to a maximum of 8 mm.
• Before making a cut, check that the stop rail
(27a) and the saw blade (5) cannot collide.
• Secure the locking lever (27b) again.
• Move the machine head to the top position.
• Fix the rotary table (9) in the 0° position.
• Loosen the set screw (23) and use the handle (2)
to angle the machine head to the left, until the
pointer (25) indicates the desired angle measure-
ment on the scale (24).
• Re-tighten the fixing screw (23).
• Cut as described in section "Cross-cutting".
Saw blade replacement (Fig. 5)
• Pull out the mains plug.
• Place the saw unit in „cross-cutting" position
• Unlock the moving saw blade guard (6) by pressing
the lock (3 - Fig. 1); in the process, raise the saw
blade guard so that the saw blade is free.
• Actuate the spindle lock (22 - Fig. 3).
• Loosen the saw blade fastening screw (28) - (At-
tention: left-handed thread).
• Remove the screw (28) and saw blade flange (29).
• Carefully remove the saw blade (risk of injury from
the saw blade teeth).
• Place a new saw blade on the inner saw blade
flange. In the process, observe the rotational di-
rection of the saw blade.
• Fit the outer saw blade flange and firmly tighten
the screw.
• Move the saw blade guard back to the correct po-
sition.
Replacing laser batteries (Fig. 6)
• Remove the laser battery cover (30). Remove the
2 batteries.
• Replace both batteries with the same or an
equivalent type. Make sure that they are inserted
with the same polarity as the used batteries.
• Close the battery cover.
Switch ON / switch OFF the laser
To switch on: Move the ON/OFF (33) switch of the
laser (34) to the "1" position. A laser line is project-
ed onto the material you wish to process, providing
an exact guide for the cut.
To switch off: Move the ON/OFF switch of the la-
ser to the "0" position.
Adjusting the laser (Fig. 7)
If the laser (31) ceases to indicate the correct cutting
line, you can readjust the laser. To do so, open the
screws (32) and set the laser by moving sideways to
that the laser beam strikes the teeth of the saw blade
(5).
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
(Fig. 6)

Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply
with these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is
often damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been
cut due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for dam-
age regularly. Make sure that the connection cable
does not hang on the power network during the
inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V ~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment
may only be carried out by an electrician.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate