Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Commissioning - Scheppach Hc52Dc Originalbetriebsanleitung

Vorschau anzeigen Andere Handbücher für HC52DC:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Do not smoke during the spraying process or in the
working area. Risk of explosion! Paint vapours are
also highly flammable.
• Fireplaces, naked flames lights or sparking machin-
ery must not be present or operated.
• Do not store or consume food or drinks in the work
area. Paint fumes are harmful to health.
• The working area must be larger than 30 m³ and suf-
ficient air exchange must be ensured during spray-
ing and drying.
• Do not spray into the wind. Always observe the reg-
ulations of the local police authorities when spraying
flammable or hazardous spraying materials.
• Do not use media such as white spirit, butyl alcohol
and methylene chloride in conjunction with the PVC
pressure hose. These media destroy the pressure
hose.
• The work area must be separated from the compres-
sor so that it cannot come into direct contact with the
working medium.
Operation of pressure vessels
• Anyone who operates a pressure vessel must keep
this in good working order, operate and monitor it cor-
rectly, perform the necessary maintenance and ser-
vicing works immediately and implement safety meas-
ures as required according to the circumstances.
• The regulatory authority can instruct necessary
monitoring measures in individual cases.
• A pressure vessel must not be operated if it exhibits
a defect that poses a danger to personnel or third
parties.
• Check the pressure vessel for rust and damage
each time before use. The compressor shall not be
operated if the pressure vessel is damaged or rusty.
If you discover damage, please contact the custom-
er service workshop.
Store the safety instructions safely.

6. Technical data

Mains power connection
Engine output
Operating mode
Compressor speed
Pressure vessel volume
Operating pressure
24 | GB
Theo. Suction capability
Theo. Power output
Protection category
Device weight
Oil (15W 40)
Max. installation altitude
(above sea level)
Subject to technical changes!
S1 = Continuous operation
The noise emission values have been determined in
accordance with EN ISO 3744.
Wear hearing protection.
Exposure to noise can cause hearing loss.
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB (A), please
wear suitable hearing protection.
Sound power level L
Sound pressure level L
Uncertainty K
7.
• Before connecting, make certain that the data on the
type plate matches with the mains power data.
• Prior to initial commissioning, remove the transport
plug (B) and fill the compressor pump housing with
oil as described in item 8.4.
• Check the device for transport damage. Report
any damage immediately to the transport company
which was used to deliver the compressor.
• Install the compressor near the point of consumption.
• Long air lines and supply cables (extension cable)
should be avoided.
• Ensure that the intake air is dry and dust-free.
230 V / 50 Hz
• Do not deploy the compressor in damp or wet areas.
2200 W
• Operate the compressor only in suitable areas (well
ventilated, ambient temperature +5°C to 40°C).
S1
There must be no dust, acids, vapours, explosive
2,850 rpm
gases or inflammable gases in the room.
50 l
• The compressor is designed to be used in dry
rooms. It must not be used in areas where splashed
approx. 8 bar
water is present.
www.scheppach.com
wA
pA
wA/pA

Before commissioning

approx. 412 l/min
approx. 272 l/min
IP32
approx. 41 kg
approx. 0.25 l
1000 m
93 dB
71.2 dB
2.03 dB
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

590610190159061019425906101901-50

Inhaltsverzeichnis