• Risk to health from wood dust or wood chippings.
The type of wood and degree of drying has an influ-
ence on the exposure to dust. Use a chip extraction
system if necessary.
• Risk to health due to noise. The permissible noise
level is exceeded during operations. Therefore, it is
essential that personal protective equipment, such
as hearing protection, is worn.
• Hazard due to electrical power, with the use of im-
proper electrical connection cables.
• Injuries due to a defective saw blade. Check the integ-
rity of the saw blade regularly and before each use.
• The noise emission can be reduced by using a spe-
cific saw blade.
• Injuries due to the workpiece being ejected at high
speed due to improper holding or guiding.
Attention: Danger of accidents!
The wood must always rest on both sides of the saw blade in the prism of the swivel frame. (see arrows)
7.
Technical data
Engine
Rated input P1
Power output P2
Operating mode
Rated idle speed
Engine brake
Engine brake type
Dimensions L x W x H
Saw blade
Weight
Wood Ø min. / max.
Wood length min. / max.
230 V / 50 Hz
2.2 kW
1.5 kW
S2 15 min*
2800 rpm
yes
mechanical
1002 x 737 x 1046 mm
405/30/3.2 mm Z32
39 kg
30 - 140 mm
300 - 1000 mm
www.scheppach.com
• Danger due to accidental start-ups of the machine:
The operating button may not be pressed when in-
serting the plug in a socket.
• Damage to property caused by unsuitable tools.
Only use the tool recommended for the application.
This is how to ensure that your machine provides
optimum performance.
• When using special accessories, the operating in-
structions enclosed with the special accessories
must be observed and read carefully.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
Protection category
Protection class
Subject to technical changes!
*Operating mode S2, short-term operation with con-
stant load
The mode comprises of a start-up period, a time with
constant load and an idle time. The operating time is
15 mins, the relative duty cycle is 25% of the operating
time.
Noise
m Warning: Noise can have serious effects on your
health.
If the machine noise exceeds 85 dB, please wear suit-
able hearing protection.
IP 54
I
GB | 31