2. Line voltage: Connect power cord to line voltage specified on motor and
nameplate. Power cord must be connected to a constant source of power (not a
fan or other device that runs intermittently). If power cord does not have a plug,
wiring is as follows: green (or green/yellow)—ground. Black (or brown)—line.
White (or blue)—neutral.
3. Safety switch: The safety overflow switch should be connected to a class II low
voltage circuit. To control a thermostatic circuit the COM and NO connections from
the safety switch are to be wired in series with the low voltage thermostat circuit to
shut down the heating/AC circuit. The COM and NC switch contacts may be used
to actuate a low voltage alarm circuit (connected in series) if the heating/cooling
system cannot be disrupted. The safety switch comes from the factory with leads
connected to the COM and NO switch terminals. Typical hook-up of "NC" circuits
would be (Figures 2 & 3),
4. If fused plug is used on 230V units, a 1.0 amp fuse is recommended.